CFJJD - 2147 LIGHTWEIGHT BODY FILLER
- MSDS: CFJJD
- Manufacturer: DYNATRON BONDO CORP
- Product Name: 2147 LIGHTWEIGHT BODY FILLER
- National Stock Number: 8010-00F022132
Product Identification
Product ID:2147 LIGHTWEIGHT BODY FILLER
MSDS Date:03/09/1995
FSC:8010
NIIN:00F022132
MSDS Number: CFJJD
Responsible Party
ATLANTA, GA 30331-1098
US
Emergency Phone: 404-696-2730/800-241-3386
Info Phone: 800-241-3386/404-696-2730
Cage: 16522
Contractor
Telephone: 404-696-2730
Cage: 16522
Ingredients
DIETHYLENE GLYCOL, MALEIC ANHYDRIDE, PHTHALIC ANHYDRIDE
CAS: 26123-45-5
Fraction By Weight: <35%
STYRENE, STYRENE MONOMER (SUSPECTED ANIMAL/HUMAN
CAS: 100-42-5
RTECS: WL3675000
Fraction By Weight: <18%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TALC (POWDER), (ASBESTOS FREE), TALCUM; HYDROUS MAGNESIUM
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: <50%
OSHA PEL 2 MG/CUM (RESP DUST)
ACGIH TLV: 2 MG/CUM (RESP DUST)
GLASS OXIDE, FIBER GLASS WOOL, LEAD BOROSILICATE GLASS
CAS: 65997-17-3
Fraction By Weight: <50%
216 G/L
RTECS: 9999999VO
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: MAY CAUSE IRRITATION.
INHALATION: VAPORS MAY CAUSE MUCOUS MEMBRANE & UPPER RESPIRATORY
TRACT IRRITATION. REPEATED EXPOSURE TO HIGH CONCENTRATIONS OF VAPOR
MAY CAUSE LIVER & KIDNEY DAMAGE.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION, DISCOMFORT.
Medical Cond Aggravated by Exposure:INDIVIDUALS W/CHRONIC RESPIRATORY
CONDITIONS (ASTHMA, CHRONIC BRONCHITIS, EMPHYSEMA).
First Aid
First Aid:EYES: FLUSH W/LARGE AMOUNTS OF WATER. SKIN: WASH THOROUGHLY
W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF
NEEDED. INGESTION: DON'T INDUCE VOMITING. OBTAIN MEDICAL ATTENTION
IN AL L CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:90F (SEE SUPP)
Lower Limits:1.1
Upper Limits:6.1
Extinguishing Media:SMALL FIRES: CO2, DRY CHEMICAL. LARGE FIRES: FOAM,
WATER FOG.
Fire Fighting Procedures:DENSE SMOKE SERIOUSLY LIMITS VISIBILITY. VENT
SMOKE & USE GAS MASK/REMOTE AIR SUPPLY. WEAR MSHA/NIOSH APPROVED
SCBA W/PROTECTIVE EQUIPMENT.
Accidental Release
Spill Release Procedures:REMOVE SOURCES OF IGNITION. INCREASE
VENITLATION TO MAXIMIZE VAPOR DISPERSAL. DIKE TO PREVENT RUNOOF
INTO SEWERS/WATERWAYS. MATERIAL MAY BE REMOVED BY SHOVELING,
WIPING. SWEEP/CLEAN W/INERT MATERIALS & PLACE IN CLOSED CONTAINER
FOR DISPOSAL.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY AREA. DON'T STORE
IN DIRECT SUNLIGHT. USE W/ADEQUATE GENERAL & LOCAL EXHAUST
VENTILATION TO MINIMIZE EXPOSURE TO VAPORS.
Other Precautions:BOND & GROUND CONTAINERS FOR TRANSFER OF PRODUCT TO
PREVENT STATIC SPARKS. AVOID PROLONGED/REPEATED CONTACT W/SKIN &
EYE CONTACT. STYRENE VAPORS ARE UNIHIBITED & MAY CAUSE BLOCKAGE OF
VENTILATION VENT S DUETO POLYMERIZATION.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR/DUST
RESPIRATOR TO AVOID INHALATION OF EXCESSIVE AIR CONTAMINANTS.
Ventilation:LOCAL EXHAUST SHOULD BE USED TO CONTROL THE EMISSION OF AIR
CONTAMINANTS. GENERAL DILUTION MAY REDUCE AIR CONCENTRATIONS
Protective Gloves:POLYVINYL ALCOHOL/POLYETHYLENE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:SAFETY SHOWERS & EYE WASH STATIONS.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. CLEAN HANDS W/SOAP & WATER AFTER EVERY USAGE.
Supplemental Safety and Health
THE PHYSICAL DATA INFORMATION IS FOR STYRENE.
Chemical Properties
Boiling Pt:B.P. Text:293F(SUPP)
Vapor Pres:5.2(SUPP)
Vapor Density:3.6(SUPP)
Spec Gravity:1.05-1.35
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE PASTE W/STYRENE ODOR
Percent Volatiles by Volume:18
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES, OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, ELECTRICAL EQUIPMENT, SPARKS, OPEN
FLAME.
Hazardous Decomposition Products:CO, CO2, HYDROCARBONS, ORGANIC ACIDS.
Conditions to Avoid Polymerization:UNREGULATED CONTACT W/ORGANIC
PEROXIDES, EXPOSURE TO HEAT, OPEN FLAME & PROLONGED STORAGE >100F.
Disposal
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS. IF DISCARDED, MATERIAL & CONTAINERS ARE CONSIDERED
RCRA HAZARDOUS WASTES BASED ON THE CHARACTERISTIC OF IGNITABILITY.
UN1866.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.